ADDITIONAL INSTRUCTIONS FOR EXPORT MODELS

(not U.S. or Canada)

Contact the distributor that sold the appliance or: Maytag International, 8700 W. Bryn Mawr Avenue, Chicago,
Illinois USA 60631, 773-714-0100, for information on product, shipping damage, replacement parts and
accessories.

Maytag dryer models manufactured for operation on 60 Hz AC are not designed for use on 50 Hz AC
electrical service and conversion of the product from 60 to 50 Hz operation is not recommended. For
additional information on 50 Hz products, contact Maytag International.

The electric service requirements can be found on the data label located on the front of the dryer behind the
door.

EXPORT ELECTRIC MODELS

Export electric models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt, 60 Hz
approved electric service. A two-wire approved electrical service with a 30 ampere fuse or circuit breaker is
r e q u i r e d . The dryer must be properly grounded with a ground wire.

IMPORTANT: When permitted by local codes, the dryer electrical supply may be connected by means of a
new power supply cord kit, marked for use with clothes dryers, that is agency listed, rated at 240 volts
minimum, 30 amperes with two No. 10 copper wire conductors terminated with closed loop terminals, open-
end spade lugs with turned up ends or with tinned leads.

Do not reuse a power supply cord from an old dryer. The power cord or electric supply wiring must be
retained at the dr yer cabinet with a suitable agency listed strain relief.

2-WIRE AND GROUND SYSTEM CONNECTIONS

Remove the terminal block cover plate.

I n s e rt the power cord with an agency listed strain relief through
the hole provided in the cabinet near the terminal bl o ck . N o t e, a
strain relief must be used.

Do not loosen the nuts already installed on the terminal block.
Be sure they are tight. Use a 3/8” (1 cm) deep well socket.

Secure the power cord ground wire to the terminal block
support using the ground screw.

If the power cord has terminals, place the terminals over the
existing nuts on the posts. The neutral wire in power cord
must be connected to the center (silver colored) post of the
terminal block.

Secure in place using the nuts provided in the parts pack a g e.
If the power cord does not have term i n a l s, use the cupped
washers ahead of the nu t s.

Be sure the terminal bl o ck nuts are tight. Secure the power cord in position. Tighten the strain relief screw(s) in
order to clamp the strain relief to the cord.

Replace the terminal block cover.

BEFORE OPERATING OR TESTING, be sure the machine is properly grounded.

EXPORT GAS MODELS

Export gas models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt, 60 Hz AC
approved electrical service with a 15 ampere fuse or circuit breaker.

Export gas models have been manufactured for use with natural gas having a higher heating value of
approximately 1025 BTU per cubic foot. Conversion to LP gas with a higher heating value of approximately
2500 BTU per cubic foot must be performed by a qualified service technician. A conversion kit is available.

2-Wire and Ground System

Neutral

Post

Neutral

Power

Cord

Ground

Wire

Power

cord

and

strain

relief