Leprecon LP-1600 Series User Manual
Page 8
![background image](https://www.manualsdir.com/files/795054/content/doc008.png)
8
7. RS-232
Standard Models only:
P C Connection
Pin
Description
DB-9 DB-25
2
Data into LP-1600 3 2
3
Data out of LP-1600 2 3
5
Ground
5 7
8. DMX Out
Industry Standard DMX Connection:
Pin
Description
1
Common
2
Data 1-
3
Data 1+
4
Data 2-
5
Data 2+
9. Reset
Recessed system reset switch.
10. MIDI Out
Industry standard MIDI output connection.
11. MIDI In
Industry standard MIDI input connection.
12. Audio Gain
Rotate clockwise to increase audio input sensitivity.
13. Audio In
Standard ¼” phono plug.
2.1. Power requirements
The LP-1600 console is powered from a separate AC input power supply. The
power supply includes an IEC type power cord, such as is used with Personal
Computer power supplies. The LP-1600 power supply requires less than two
amps of input power.
The power supply furnished with the LP-1600 will operate with voltages from
90 to 240 volts, with a frequency of 50 or 60 HZ. This supply should be
acceptable for standard voltages anywhere in the world.
Because temporary power distribution is usually set up for portable lighting
systems, it is possible to accidentally connect the console to a higher line
voltage, or to a source where two of the three line wires (for example, the hot
wire and the ground wire) have been swapped. Some protection from such
accidents has been designed into the LP-1600, but serious damage to the
board and operator can still result from incorrect power connections. It is