beautypg.com

La Crosse Technology WS-3610 User Manual

Page 40

background image

37

15 Technical

Data

15.1

Outdoor Data:

Transmission Range in Open Field:.....up to. 330 ft max.
Measuring Interval Outdoor Data:........every 20 s
Temperature Range: ............................-40 °F to 139.8 °F

(Display “OFL” outside
this range)

Resolution: ...........................................0.1 °F
Measuring Range Rel. Humidity: .........1% to 99%
Resolution: ...........................................1%
Rain Volume Display:...........................0 to 39.4 in (1 hr, 24 hrs.)

0 to 98.4 in (last week,
last month)

0 to 393.7 in (total
volume)

Resolution: ...........................................approx. 0.02 in
Wind Speed..........................................0 to 111.8 mph or 1 to 50

m/s

Resolution: ...........................................0.1 m/s
Wind Direction:.....................................Graphic Resolution 22.5

Degrees,

Numeric

Resolution

Character Format

15.2

Data Transmission by 433 MHz Signal:

Measuring Interval Thermo-Hygro Sensor:.......................
128 s (at Wind speed ≤ 6.2 mph) or 32 s (at Wind speed > 6.2
mph, or on Wind Gust display); 10 Min.

(if the Base Station does

not receive any data after 5 successive attempts all outdoor
displays except the rain amount revert to “---“)

15.3

Data Transmission by Cable:

Measuring Interval Thermo-Hygro Sensor:..........32 s