Datalogic Scanning QUICKSCAN QS2500 User Manual
Page 49
Product Reference Guide
45
•
Append label data with Concatenation Code
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
Checksum Transmission
Disable
00*
Enable
01
Max. Code Length
Use Global Max.
00*
1–64
01–64
Min. Code Length
Use Global Min.
00*
1–64
01–64
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ff
hex
ASCII
code
00–ff
hex
<#>*
Insertion Group
Selection
0–44
00–44
00*
Format
Standard
00*
UCC/EAN-128
01
$
Start Program