SPECIAL NOTE

After installation or any servicing operation, always ensure that

the appliance is gas sound and that the components are now

operating correctly. Items removed during servicing should be

replaced in the reverse order to their

removal.

In order to change the work-top injectors,

it is necessary to act as follows:

- remove the grids

- remove burners

and flame-spreaders.

GAS ADJUSTEMENTS

- change the injectors

- adjust the minimum flow

‘When converting from Natural Gas to U-LPG ensure that

the NG regulator is removed and replaced with the Test Point

Assembly. A gas regulator suitable for a supply pressure of 2.75kPa

should be part of the gas tank supply and should be adjusted with

the wok burner operating at maximum.
REPLACEMENT OF THE INJECTORS

When required to operate on other gas replace the injectors in

accordance with information referred to in chart below.

6

- change the injector (see Fig. C) and replace it with another one

suitable for the new type of gas (see tab. 1)

Fig. C

Z

Fig. 2B

Fig. 2A

MINIMUM FLOW ADJUSTMENT FOR HOB-TOP TAPS

In order to adjust the minimum flame setting proceed as follows:

switch the burner on, and set the knob at the minimum position

. Remove the knob from the tap, place a small bladed screwdriver

down the centre of the tap shaft (fig. 2A).

Attention: on taps with a security valve, the minimum adjusting

screw «Z» is on the body of the gas tap (fig. 2B).

Unscrew the adjusting screw in order to increase the flow or screw

it to decrease the flow.

The correct adjustment is obtained when the flame has a length

of about 3 or 4 mm.

For butane/propane gas, the adjusting screw must be screwed

in thigt.

Make sure that the flame does not go out turning quickly from the

max. flow to the minimum flow .

Refit the knob again.

ELECTRICAL CONNECTION

‘In order to avoid hazard, any electrical work performed on this

equipment or its associated wiring, should only be done by persons

authorised by the supplier or similarly qualified persons.’

TAB. 1

0.53

Auxiliary 3.7

0.73 Semi-rapid

7.0

0.95

Rapid 11.7

LP Test point

adaptor

1.00 Triple Crown

12.7

U - LPG 2.75 kPa

Jet mm Ø

Burners Power MJ/h

Gas Type kPa

Natural Gas 1.00 kPa

0.90

Auxiliary 4.0

1.20 Semi-rapid

7.1

1.50

Rapid 11.0

Jet mm Ø

Burners Power MJ/h

1.63 Triple Crown

12.7

NG Regulator

Gas Type kPa

ELECTRICAL CONNECTION

The appliance must be installed by a suitably qualified person in

accordance with these instructions and with the requirements of

the Australian Wiring Rules AS/NZS 3000.

Fixed wired installations are to be provided with suitable isolation

means in accordance with the said rules.

Any plug socket installed for the purpose of connecting the

appliance to supply must be readily accessible when the appliance

is installed.

Before making the connection, make sure that:

1) the safety circuit-breaker and the electrical system are able to

withstand the load of the appliance

(see nameplate).

2) the power supply system has an earth connection in good

working order in accordance with the regulations in force;

WARNING: THIS APPLIANCE MUST BE EARTHED.

The flexible mains lead and plug must not be in contact with hot

surfaces.

IMPORTANT

The wires in the mains lead are coloured in accordance with the

following code:

GREEN & YELLOW.........................................................EARTH

BLUE...........................................................................NEUTRAL

BROWN ...............................................................................LIVE

Electric power........1,5 mm

2

core cable (15 amp. Fuse required)

Should conform to local authority requirements.

Also refer to rangehood manufacturers recommendations.

This appliance is supplied with a plug & cord, simply plug into a

3 pin household socket outlet witch is properly earthed.