GAS CONNECTION

Should conform to gas utility regulations e.g. AS5601 Gas

installations; also refer to rangehood manufacturers

recommendations.

Check gas pressure, note the correct setting from the data plate

sealed inside the front appliance drawer .

This appliance from the factory suitable for NATURAL gas but, if

necessary, can be adjusted for U-LPG by authorised person.

*

Before Leaving - Check all connections for gas leaks with soap

and water. DO NOT use a naked flame for detecting leaks. Ignite

all burners to ensure correct operation of gas valves, burners and

ignition. Turn gas taps to low flame position and observe stability

of the flame.

When satisfied with the cooker, please instruct the user on the

correct method of operation.

In case the appliance fails to operate correctly after all checks

have been carried out, refer to the authorised service provider in

your area.’

GAS CONVERSION AND ADJUSTMENT

When used with natural gas all burners have been preset at our

factory and further adjustment should not be necessary. Conversion

kits to other gases are available from the place of purchase. Do

not attempt to fit the conversion kit yourself. Conversion to U-LPG

gas should only be carried out by an authorized technician.

the characteristics of the gas and electricity output.

The appliance is generally preset for natural gas (so no other

adjustment is necessary) ensure regulator is fitted for N.G.

Ensure that all foreign matter has been cleared from the gas

supply line and also purge all air from the gas system. Connect

to regulator, tighten and check the installation to ensure no gas

leaks occur.

accordance with the manufacturer’s installation instructions,

relevant local fitting regulations, municipal building regulations,

and 695mm from the floor (depends on adjustment of feet).

The appliance shall be installed by an authorized person in

For the adjustments to U-LPG please operate as specified in the

paragraph GAS CONVERSION AND ADJUSTMENT (pag 4).

The Gas Connection is male 1/2" BSP and is situated at the right

hand rear of the appliance, approximately 40mm from the side

This appliance can be connected with rigid pipe as specified in

AS5601 table 3.1 or with a

Plumbezy Flexible hose, AGA

Approval number 6196, 10mm

ID, class D and between 1-1.2m

long in accordance with AS5601

for a 'high level connection'.

Ensure that the chain prevents

stress on the hose assembly

when the cooker is moved out

of its normal operating position.

TO FIX THE COOKER TO THE REAR WALL
WARNING -
For safety reasons and to prevent tipping of the appliance,

these stabilizing means must be installed.

The cooker is equipped with 2 chains fixed on each side at the rear of

the cooker near the top (see Fig. A). The chains are fitted with “spring

clips” which must be clipped to the “screw eyes” provided with the cooker.

Install the “screw eyes” as follows :

1. Drill four 6mm holes (position 1 - 2 - 3 - 4) in the wall

as in Fig. A.

2. Insert part “R” into the holes then screw in the “screw eyes” part

“G” see Fig. B.

Note: If the part provided is not suitable for the wall material please

use an appropriate device to ensure secure holding of the “screw

eyes” to the wall.

3. Bring the cooker near the wall and clip the chains on the

“screw eyes” as in Fig. C.

IMPORTANT: If the cooker is moved for any reason

(e.g. maintenance) resulting in the cooker being unclipped from the

wall, the cooker must be re-clipped to the wall at the completion of

the task.

other relevant statutory code band regulations. If you have some

doubts, please contact the authorities for confirmation concerning

the AS5601 code for gas burning appliances and equipment and

IT IS RECOMMENDED THAT A SERVICE TAP AND UNION BE

FITTED ADJACENT TO THE APPLIANCE INLET TO FACILITATE

FUTURE SERVICING.

5 burner models: set the burner pressure to 1kPa for Natural Gas

and 2.75kPa for U-LPG with the wok burner operating a full rate’.

For commissioning of the appliance with the Oara 97

regulator for Natural Gas, the test point pressure should

be 1.00kPa with all burners operating on HIGH.

Apply a manometer to the test nipple and reset the regulator if

necessary. Do not forget to replace the test nipple screw and to

leave the instructions book with the user.
VERY IMPORTANT FOR THE INSTALLER

Do not attempt to turn or stress threaded elbow of the manifold:

you risk damage to this part of the gas appliance which may void

the manufacturers warranty.

Fig. B

Fig. C

G

wall

wall

Fig. A

76 mm

550 mm

G

R

Hole

55 mm

chain

Position

1

Position

2

55 mm

Position

3

Position

4