beautypg.com

Installation instructions – Kleenmaid DCTI User Manual

Page 11

background image

11

Installation
these instructions are aimed at qualified fitters as a guide

to installation, adjustment and maintenance in compliance

with the laws and standards in force. The operations must

always be carried out with the appliance disconnected from

the electricity supply.

Positioning (Fig. 8-9-10-11)
The appliance is made to be fitted into a counter top, as

show in the figure. Apply the sealant supplied around the

whole perimeter of the hob. Installation over an oven is not

recommended, but if this is necessary, check that:

- the oven has an efficient cooling system;

- there is no passage of hot air from the oven to the hob;

- allow air passages as shown in the figure.

Electrical connection (Fig. 12-13)
Before connecting to the electricity supply, ensure that:

- the characteristics of the system are such as to satisfy

that indicated on the registration plate applied to the

bottom of the hob;

- the system has an effective earth connection compliant

with the standards and laws in force. Connection to earth

is compulsory by law.

If the appliance has no cable and/or plug, use material

suitable for the absorption indicated on the registration plate

and for the working temperature. The cable must not reach

a temperature higher than 50°C above room temperature

in any point.

For direct connection to the network it is necessary to fit an

omnipolar switch of a suitable size to ensure disconnection

of he network with a contact opening distance that allows

complete disconnection in the conditions of the overtension

category III, compliant with the installation regulations (the

yellow/green earth wire must not be interrupted).

The omnipolar socket or switch must be easy to reach when

the appliance is installed.

N.B.:

- The manufacturer declines all responsibility if the

usual accident prevention standards and the above

instructions are not observed.

If the power cable is damaged, it must be replaced by the

manufacturer or by the manufacturer’s technical servicing

network, or by a similarly qualified operator, to prevent

every possible risk.

Installation instructions

381

+1

0

511

+1 0

360

+1

0

490

+1 0

R

12

1.

5

INDUCTION

INDUCTION

380

510

R 11

63

1

Fig. 8

N.B. For the Semifilo

version, it is not necessary

to lower the hob by 1.5

mm.

Mod. DCTI