background image

ELECTRICAL CONNECTION INSTRUCTIONS

8.3

Electrical Loads

Gas appliances referred to in this manual have a maximum electrical load of 5W.

ELEMENT

CB355

CC29/E

CC605D/E

CC805D/E

BBQ

2x1200W

-

-

-

SMALL

-

1200W

2x1200W

2x1200W

MEDIUM

-

-

1800W

1800W

LARGE

-

1800W

2200W

2200W

OVAL

-

-

-

2400W

TOTAL

2.4 kW

3.0 kW

6.4 kW

8.8 kW

When connected to a subcircuit protected by a circuit breaker, the current drawn by an appliance may cause the
circuit breaker to trip in some cases. It is recommended that the following installation procedures are used.

NOTE: Larger cable sizes may be required to conform with AS3000 depending on length and method of enclosure
of supply cable.

Model

kW Rating

Maximum Current

Recommendation

(Amperes)

Cable Size

Circuit Breaker

CB355

2.4

10.0

1.5 mm

2

10 Amp

CC29/E

3.0

12.5

1.5 mm

2

15 Amp

CC605D/E

6.4

26.7

2.5 mm

2

30 Amp

CC805D/E

8.8

36.7

4.0 mm

2

40 Amp

28