Kleenmaid CC29 User Manual
Page 30
ELECTRICAL CONNECTION INSTRUCTIONS
8.3
Electrical Loads
Gas appliances referred to in this manual have a maximum electrical load of 5W.
ELEMENT
CB355
CC29/E
CC605D/E
CC805D/E
BBQ
2x1200W
-
-
-
SMALL
-
1200W
2x1200W
2x1200W
MEDIUM
-
-
1800W
1800W
LARGE
-
1800W
2200W
2200W
OVAL
-
-
-
2400W
TOTAL
2.4 kW
3.0 kW
6.4 kW
8.8 kW
When connected to a subcircuit protected by a circuit breaker, the current drawn by an appliance may cause the
circuit breaker to trip in some cases. It is recommended that the following installation procedures are used.
NOTE: Larger cable sizes may be required to conform with AS3000 depending on length and method of enclosure
of supply cable.
Model
kW Rating
Maximum Current
Recommendation
(Amperes)
Cable Size
Circuit Breaker
CB355
2.4
10.0
1.5 mm
2
10 Amp
CC29/E
3.0
12.5
1.5 mm
2
15 Amp
CC605D/E
6.4
26.7
2.5 mm
2
30 Amp
CC805D/E
8.8
36.7
4.0 mm
2
40 Amp
28