beautypg.com

Kleenmaid CC29 User Manual

Page 28

background image

GAS CONNECTION INSTRUCTIONS

7.2

Injector Sizes for Gas Cooktops

9. Turn on each burner control and light in turn. Check for a clear blue flame without excessive yellow tipping.

If burners show any abnormal combustion check they are correctly located. Sometimes burners may not
ignite immediately and may seem to “blow” slightly when they do ignite. This is usually due to air in the gas
line, which should clear itself.

10. If, after following the instructions, satisfactory performance cannot be obtained, contact the local gas authority

for advice and assistance.

11. For minor adjustments see Servicing and Minor Adjustments.
12. A two (2) yearly inspection of the appliance by an authorised service agent will ensure many years of trouble

free service (Note: This is not provided under warranty).

MODEL

BURNER

NATURAL GAS

ULPG

INJECTOR Ø mm

MJ/hr

INJECTOR Ø mm

MJ/hr

CG29

RAPID

1.60

12.0

0.92

11.0

SEMI-RAPID

1.18

6.0

0.65

5.4

CG29WOK

WOK

1.80

14.5

0.95

12.0

CG60WOKFFE

RAPID

1.60

12.0

0.92

11.0

SEMI-RAPID

1.18

6.0

0.65

5.4

WOK

1.80

14.5

0.95

12.0

CG90WOKFFE

RAPID

1.60

12.0

0.92

11.0

SEMI-RAPID

1.18

6.0

0.65

5.4

AUXILIARY

0.90

4.0

0.5

3.2

WOK

1.80

14.5

0.95

12.0

CG90WOKFFEF

SEMI-RAPID

1.18

6.0

0.65

5.4

AUXILIARY

0.90

4.0

0.5

3.2

WOK

1.80

14.5

0.95

12.0

FISH

1.4

9.5

0.85

10.0

26