beautypg.com

6 cable connections – Kemppi Evo 170 User Manual

Page 8

background image

EN

2.6 Cable connections

Connection to the mains
The machine is fitted with a 3 m long supply voltage cable and plug. Connect the supply

voltage cable to the mains. Should you need to fit an alternative plug or mains cable, ensure

installation is completed by an authorised electrician.

NOTE!

The fuse size needed is 16 A delayed.

If you use an extension cable, its cross-sectional area should be at least as large as the

machines supply cable (3 x 1.5 mm²). It is recommended to use 3 x 2.5 mm² extension cable.

The maximum length for the extension cable is 100 meters.
The machine can also be used with a generator. The minimum power for the generator is

4.2 kVA, and the recommended power 8.0 kVA in order for the machine to be used at

maximum capacity.
earth return
The welding circuit earth return cable is already connected to the machine. Clean the

workpiece surface and fix the earth return clamp to the work piece in order to create a

welding circuit.
Welding gun
The welding gun is already connected to the machine. The filler wire, shielding gas and

electric current is delivered to the weld inside the welding gun cable. When you press the gun

trigger, shielding gas starts to flow and filler wire feed begins. The arc ignites when the filler

wire touches the work piece. Inside the gun cable there is a factory-installed wire liner that

is best suited for welding with steel and CuSi filler wires. It can temporarily be used also with

stainless steel and aluminium wires. However, this is not recommended because of greater

friction and reduced welding performance, and it may finally lead into failure of filler wire

delivery.
If you mainly use aluminium or stainless steel filler wire, we recommend that you replace the

wire liner with a Kemppi plastic type, which is better suited for the material. For instructions

on how to change the wire liner, please refer to the Maintenance section later in this manual.
The gun neck can be rotated 360° to suit different welding positions. The neck is connected via

a standard clockwise screw thread. Always make sure that the neck is almost fully connected

to the bottom thread. This prevents damaging and overheating the neck.

NOTE!

If you intend to use other than 0.8 mm diameter steel filler wire, change the welding gun

contact tip, gun liner, and drive roll to match the selected filler wire type and thickness.