Sizes of the mains cables and fuseratings for the machine at 100 % dury cycle are specified in the

table below:

Master 5001

Rated voltage

3~ 400 V

Mains voltage range

400 V ± 10 %

Fuses, delayed

35 A

Connection cable mm²

4 x 6,0 S

In cables of S type there is a protective grounding conductor coloured green-yellow.

2.4. WELDING AND EARTH CABLES

Use only copper cables with cross-sectional area of at least 50 …95 mm².
In enclosed table are shown typical load capacities of rubber insulated copper cables, when ambient

temperature is 25ºC and lead temperature is 85 ºC.

Cable

Duty cycled ed

Voltage loss /10 m

100% 60%

30%

50mm²

285 A 370 A 520 A

0,35 V/ 100 A

70 mm²

355 A 460 A 650 A

0,25 V/ 100 A

95 mm²

430 A 560 A 790 A

0,18 V/ 100 A

Do not overload welding cables due to voltage losses and heating.
Fasten the earthing press of the return current cable carefully, preferably direct onto the piece to

be welded. The contact surface of the press should always be as large as possible.
Clean the fastening surface from paint and rust.

2.5. MOUNTING OF POWER UNIT TO TRANSPORT CARRIAGE

Read mounting instructions for Master 5001 power source delivered with carriage T12. Fasten

power source carefully of that the equipment should withstand lifting with lifting device.