Err 5: PROCOOL cooling unit has stopped welding. Reason can be break of supply voltage

from PROCOOL, pressure of liquid circulation doesn´t arise or temperature of cooling liquid

has arisen too high.

Err 6: Wire feed unit has stopped welding in liquid position of selecting switch S12 of air/liquid-

cooled gun for PROMIG, because data communication to cooling unit is broken (defect in

intermediate cable or in connection).

Err 7: Selecting switch S12 of air/liquid-cooled gun for PROMIG is in air position, PROCOOL

is switched-on and start switch is pressed down. Purpose of operation is to prevent the

liquid-cooled gun from being destroyed, if the selecting switch S12 for air/liquid-cooling is

in wrong position.

Err 8: Liquid-cooled PMT gun is overheated.

Err 9: Overload of wire feed motor, which can be caused e.g. by blocked wire guide of gun or

by gun cable, which is too much curved.

Err 10: Operation of thermal release of PRO power source has stopped welding.

Err 11: You try to use the PMT gun, when their use is prevented with the 5. jumper operation.

Err 12: Welding has been stopped, because so called door switch or gas guard has operated

(operations need extra mountings to standard unit).

Eliminate the error codes as follows:

Error code Err 1 is eliminated when PROMIG wire feed system is set into MIG state.

Blinking of error codes Err 2-4 ends automatically within 5 s, if the trigger is not pressed down.

Eliminate the reason of error before next start.

Blinking of error codes Err 5-12 ends by next start, if the reason of error code has been

eliminated.