Accessories, Electrical connections – Datalogic Scanning DS6500-100-015 User Manual
Page 16
DS6500 ETHERNET MODEL
SOFTWARE FEATURES
ENVIRONMENTAL FEATURES
Interleaved 2/5
Readable Codes
Code 39 standard
Operating
Temperature
0° to +40 °C (+32 to +104 °F)
Codabar
Code 128
Storage
Temperature
-20° to +70 °C (-4° to +158 °F)
EAN 128
Humidity
90% non condensing
Code 93 (Standard & Full ASCII) Ambient Light
EAN/UPC (including Add-on 2
Immunity
3500 lux
And Add-on 5)
Vibration Resistance 14 mm @ 2 to 10 Hz
Code Selection
IEC 68-2-6 test FC
1.5 mm @ 13 to 55 Hz
Up to 10 codes during one
reading phase
2 hours on each axis 2 g @ 70 to 200 Hz
Headers and
Shock Resistance
Terminators
Up to 128-byte headers and
128-byte terminators
IEC 68-2-27 test EA
On Line, Automatic, Test,
3 shocks on each axis
30 g; 11 ms
Operating Modes
PackTrack™
Protection Class
IP50
Config. Mode
Genius™ utility program
PHYSICAL FEATURES
Std Models
Oscill. Mirror
Dimensions mm
(inch)
110x113x99
(4.33x4.45x3.9)
113x180x104.5
(4.45x7.08x4.11)
Parameter Storage Non-volatile internal FLASH
Weight
1.5 kg (3.3 lb) 2.0 kg (4.4 lb)
Accessories:
Name Description
Part
Number
CAB-6011
Cable to C-BOX100 1 m
93A051221
CAB-6012
Cable to C-BOX100 2 m
93A051222
CAB-6015
Cable to C-BOX100 5 m
93A051223
C-BOX 100
Passive connection box
93ACC1510
INT-30
20 mA C.L. interface board for C-BOX 100
93A151022
GFC-60
90° mirror
93A201100
GFC-600
90° mirror close distance
93A201102
PWR-120
Power unit 110/230 V AC - 24 V DC
93ACC1530
BTK-6000
Terminator kit (5 pcs)
93ACC1710
PG6002
Single unit power supply – US
93ACC1718
PG6001
Single unit power supply – UK
93ACC1719
PG6000
Single unit power supply – EU
93ACC1720
FBK-6000
Fast bracket kit (2 pcs)
93ACC1721
US-60
Mounting bracket kit (5 pcs) for multisided stations
890001020
MEP-542
Photocell kit – PNP
93ACC1727
MEP-543
Photocell kit – NPN
93ACC1728
OEK-2
Optical encoder (10 m cable + spring)
93ACC1770
OEK-1
Optical encoder kit + 10 m cable
93ACC1600
Electrical Connections:
The DS6500 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and
input/output signals.
An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet),
while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the
system.
The details of the connector pins are indicated in the following table: