Datalogic Scanning DS6500-100-015 User Manual
Page 12

DS6500 PROFIBUS MODEL
26-pin D-Sub Connector Pinout
Pin Name
Function
Chassis - internally connected to GND
1 CHASSIS
Cable shield connected to chassis
20
RXAUX
Receive data of auxiliary RS232 (referred to GND)
21
TXAUX
Transmit data of auxiliary RS232 (referred to GND)
8
OUT 1+
Configurable digital output 1 – positive pin
22 OUT
1-
Configurable
digital output 1 – negative pin
11 OUT
2+
Configurable
digital output 2 – positive pin
12 OUT
2-
Configurable
digital output 2 – negative pin
16 OUT
3A
Configurable
digital
output 3 – polarity insensitive
17 OUT
3B
Configurable
digital
output 3 – polarity insensitive
18 EXT_TRIG/PS
A
External
trigger
(polarity insensitive) for PS
19 EXT_TRIG/PS
B
External
trigger
(polarity insensitive) for PS
6
IN2/ENC A
Input signal 2 (polarity insensitive) for Encoder
10
IN2/ENC B
Input signal 2 (polarity insensitive) for Encoder
14
IN3A
Input signal 3 (polarity insensitive)
15
IN4A
Input signal 4 (polarity insensitive)
24
IN_REF
Common reference of IN3 and IN4 (polarity insensitive)
9, 13
VS
Supply voltage – positive pin
23, 25, 26 GND
Supply voltage – negative pin
10
19
1
18
9
26
26-pin male D-sub Connector
Pin
RS232
RS485 Full-Duplex
RS485 Half-Duplex
20 mA C.L.
(INT-30 with C-BOX 100 only)
2 TX
TX485+ RTX485+
3 RX
RX485+
4
RTS
TX485-
RTX485-
see INT-30 instructions
5 CTS
RX485-
7 GND_ISO GND_ISO GND_ISO
* For 20 mA C.L. connections, GND is the same of the scanner power supply.
9-pin Lonworks Connector Pinout
Pin Name
Function
Cable shield internally connected
1 CHASSIS
by capacitor to chassis
9
VS
Supply voltage – positive pin
2
GND
Supply voltage – negative pin
6
VS_I/O
Supply voltage of I/O circuit
3 Ref_I/O
Reference voltage of I/O circuit
4 SYS_ENC_I/O
System
signal
5 SYS_I/O
System
signal
7
LON A
Lonworks line (polarity insensitive)
8
LON B
Lonworks line (polarity insensitive)
5
1
9
6
9-pin female Local Lonworks Connector
9-pin Profibus Connector
Pin Name
Function
1
Shield
Shield, Protective Ground resp. (optional)
2 Free
3
B-LINE (RxD/TxD-P) Received/Transmitted Data-P
4
CNTR-P
Repeater Control Signal (optional, RS485 level)
5
DGND
Data Ground (M5V)
6
+5 V
Voltage Plus (P5V)
7 Free
8
A-LINE (RxD/TxD-N) Received/Transmitted Data
9
CNTR-N
Repeater Control Signal
5
1
9
6
9-pin female Profibus Connector
(white)
10