Programat, Short instructions – Ivoclar Vivadent CS - Short Instructions User Manual

Page 2

background image

Programat

®

CS

– Short Instructions

Version 3
Valid as of Software V2.0

Adjustable parameters and possible value ranges

Program structure

Error messages

The furnace continuously checks all functions during operation.
If an error is detected, the respective error message is
displayed.
In case of an error, the heater switches off for safety reasons.

Index Category Error

ERR

Conti-

Error Message Text

No.

nuation

possible

1

Entry

T < B

2

Enter a logical value for T

2

Entry

L > T

8

Enter a logical value for long-term cooling L

3

Entry

V2x <= V1x

9

Enter a logical value for the vacuum-on temperature Vx1 or the vacuum-off temperature Vx2

4

Entry

V2x > Tx + 1°C

10

Change either the vacuum values or the holding time T

5

Entry

Incorrect values for V1x, V2x

11

Enter a logical value for V1x, V2x

6

System

Current temperature after

13

Excess temperature! Program aborted, furnace head opens to allow the furnace to cool down.

Start > Tx + 50 °C

*, **

8

Entry

T2 < T1

16

Enter a lower value for T1 or a higher value for T2.

9

System

Power failure > 10 s during

17

A firing program in progress was interrupted for more than 10 s. The program cannot be continued!

a firing program in progress

10

Entry

T1 > V12

18

Enter a lower value for T1 or a higher value for V12

11

Entry

vV set, but V2 is

19

Pre-vacuum activated! V2 must be higher than B.

missing or invalid

12

System

Error in the heating system

20

no

Check the heater fuse. If the fuse is O.K., contact your local Ivoclar Vivadent Service Center.

**

13

System

Heating muffle very old

23

The heating muffle is very old. It is recommended to replace it. After the error message has been
acknowledged, a firing program may still be started.

14

System

Heating muffle defective

24

The condition of the muffle is so poor that is has to be replaced immediately.

16

Entry

T is > B + 200 °C at the

26

Firing chamber too hot to start a firing program.

start of a firing program

17

System

Furnace head cannot

27

The furnace head cannot be moved to the final position. It might be blocked by an external mechanical

be initialized

**, ***

source! If this is not the case, please contact your local Ivoclar Vivadent Service Center!

18

System

The furnace head does not

28

The furnace head does not open/close correctly. The furnace head was manually moved or is obstructed.

reach the target position

**

The furnace head must only be moved using the keys intended for this purpose!

21

System

Necessary vacuum (xxxmbar) 33

The vacuum cannot be established. Check the seal of the firing chamber, vacuum hose, vacuum pump,

is not reached within 1 min.

pump fuse.

33

Entry

HV > H (H2)

110

Enter a lower value for HV or a higher value for H (H2)

35

Entry

"Share of the holding time 120

Activate the vacuum during the holding time Tx or deactivate HV.

with vacuum" is activated,
but Vx2 does not
correspond to Tx or Tx+1

38

System

Brief power failure during a 702

A firing program in progress was interrupted by a brief power failure. The program is continued!

firing program in progress

45

System

Vacuum drop

801

An unacceptable vacuum drop has occurred.

46

System

The vacuum does not

802

No vacuum increase could be measured. Check the following points: Is the firing chamber tight (no

increase (self-test)

contamination on the sealing surfaces)? Is the vacuum hose connected? Is the vacuum pump connected?
Is the fuse F1 o.k.?

75

System

ATK2 calibration:

1302

Error during calibration. Sample may not be correctly inserted. Try again with a new sample and make sure the

Pre-heating to 963 °C

**

sample makes ampl contact.

79

Note

Calibration reminder

1310

Some time has passed since the last calibration procedure. Calibrate the furnace soon.

80

Note

Dehumidification reminder

1312

Some time has passed since the last dehumidification procedure. Dehumidificat the furnace soon.

The following error messages my be displayed:

Please contact the Ivoclar Vivadent After Sales Service, if other error messages being displayed.

Symbol

Parameter

Value range

Value range

P

Program number P

1–20

B

Stand-by temperature

100–700 °C

212–1292 °F

S

Closing time (min : sec)

00:18–30:00

t(*)

Temperature increase rate

30–140 °C/min

54–252 °F/min

T

Holding temperature

100–1200 °C

212–2192 °F

H

Holding time (min : sec)

00.01–60:00

V1

Vacuum on

0 or 1–1200 °C

0 or 34–2192 °F

V2

Vacuum off

0 or 1–1200 °C

0 or 34–2192 °F

t(*)

Temperature increase rate

t2

Second stage

30–140 °C/min

54–252 °F/min

T

Holding temperature

Second stage

100–1200 °C

212–2192 °F

H

Holding time

Second stage (min : sec)

00.01–60:00

V1 (V1 2)

Vacuum on

Second stage

0 or 1–1200 °C

0 or 34–2192 °F

V2 (V2 2)

Vacuum off

Second stage

0 or 1–1200 °C

0 or 34–2192 °F

L

Long-term cooling

0 or 50–1200 °C

0 or 122–2192 °F

tL

Cooling temperature rate

0 or 1–50

0 or 32–90

(*) 100 V Version: 140°C/min (252°F/min)

Please observe the notes in the Instructions for Use of the corresponding material.

Program

Description

1

Crystallization/glaze program for IPS e.max CAD

2

Corrective firing for IPS e.max CAD

3

Speed Crystallization/glaze program for IPS e.max CAD

4

Stain and glaze program for IPS Empress CAD

5

Fusion/Crystallization program for the IPS e.max CAD-on technique

6

Characterization/glaze program for the IPS e.max CAD-on technique

7

Crystallization program for IPS e.max CAD Impulse

8 to 20

Individual Programs