Ivobase, System short instructions – Ivoclar Vivadent IvoBase System User Manual
Page 2
IvoBase
®
System
Short Instructions
4
Mixing the material
5
Loading the injector
Injection and
polymerization
Divesting
– Remove the monomer
container from the capsule
– Remove the capsule seal
– Twist off the sealing cap of
the monomer container
– Pour the monomer into the
open capsule
– Use the spatula to mix the
monomer and polymer in the
capsule to a
homogeneous
mixture
for approx. 20–30 s
– Place capsule on an even
surface
– Place flask with the centering
insert on the capsule
– Insert the flask into the
polymerization chamber
until
it stops
– Close the door of the Injector
– Select the program
– Activate "RMR" key, if desired
– Start
– Start of the program with the
expansion phase
– Remove the flask at the end
of the program
–
Cool
in cold water for
15 min.
– Remove the locking clasps
– Secure the flask in the dental
press with the
divesting aid
– Lift the upper flask half by
levering it on both sides in the
gap between the flask halves
– Turn over the flask
– Repeat the procedure
– Remove the stone core and
separate capsule
– Divest the dentures from the
stone core using
stone tongs
– Finish and polish dentures as
usual
Please refer to the Instructions for Use for more detailed information
Ivoclar Vivadent AG
9494 Schaan/Liechtenstein
639389/e/2012-12-06/Rev. 0
Program
No.
Material
Duration
Duration
with
RMR*
1
IvoBase Hybrid
35 min
45 min
2
IvoBase High Impact
50 min
60 min
3
SR Ivocap High Impact
55 min
65 min
4
SR Ivocap Clear
55 min
65 min
5
SR Ivocap Elastomer
65 min
–
6-20
Ivoclar Vivadent – spare
* With the RMR function (residual monomer reduction) the residual monomer content is reduced to below 1%.