Ivoclar Vivadent IPS Empress CAD Labside User Manual
Page 30

30
In order to individualize restorations in the incisal area so that they correspond with their natural model, the IPS Empress
CAD restoration is additionally veneered using opalescent IPS Empress Esthetic Veneer ceramic materials. The cut-back
technique is very efficient if the fully anatomical anterior crown or the veneer are first designed according to the definite
final shape. After that, the incisal third is reduced and subsequently provided with an individualized aesthetic veneer.
IPS Empress CAD Veneers / Anterior Crowns – Cut-back and layered
Please refer to the corresponding Operating Instructions and/or Manuals of the respective CAD/CAM system
for further information on the CAD/CAM processing procedure. The instructions by the manufacturer must be
observed.
IPS Empress Esthetic Veneer
Wash Pastes
neutral
low value
high value
MM
light-
salmon
MM
yellow-
orange
MM
reddish-
orange
Modifier
copper
Modifier
orange
Modifier
sky blue
Modifier
basic yellow
Modifier
basic red
IPS Empress Esthetic Veneer
Layering Materials
Incisal
Opal
HT = high
translucent
Incisal
Opal
MT = medium
translucent
Incisal
Opal
LT = low
translucent
Transpa
blue
Transpa
neutral
Incisal
edge
Incisal
white
Incisal
grey
Incisal
orange
Incisal
yellow
Incisal
orange-
pink
Chroma
Modifier
110/A1
Chroma
Modifier
210/A3
Brightener
Fully anatomical, milled veneer and anterior crown, which are reduced in the incisal area.
0.5 mm
0.5 mm
0.5 mm
approx.
0.5–1.0 mm
Veneer
Minimum thickness
of the milled objects
after the
corresponding
reduction
= 0.5 mm
Layer thickness =
Limited layering area:
labial, incisal third
0.5 mm
approx.
0.5–1.0 mm
Minimum thickness
of the milled objects
after the
corresponding
reduction
= 0.5 mm
Layer thickness =
Limited layering area:
labial, incisal third
Anterior crown