Electrical data for models sw‐48‐ri electric, Electrical data for models sw‐48‐ri gas, Electrical data for models sw‐48‐ri steam – Insinger SW-48-RI User Manual
Page 7
7
DOC SW‐48‐RI 2.2010
www.insingermachine.com
ELECTRICAL DATA for MODELS SW‐48‐RI Electric
3phase Voltage
208
230
460
Pump Motor
43.6
41.2
20.6
Control Circuit
2.0
2.0
2.0
Wash Heater (one 9kW + one 4.5 kW)
39.5
35.9
18.9
Rinse Heater (two 9kW)
50.0
45.2
22.6
Total Running Current
133.1
122.3
62.1
Exhaust
fan
(Opt.)
2.0 2.0 1.0
ELECTRICAL DATA for MODELS SW‐48‐RI Gas
3phase Voltage
208
230
460
Pump Motor
43.6
41.2
20.6
Control Circuit
2.0
2.0
2.0
Rinse Heater (two 9kW)
50.0
45.2
22.6
Total Running Current
95.6
88.4
45.2
Exhaust
fan
(Opt.)
2.0 2.0 1.0
ELECTRICAL DATA for MODELS SW‐48‐RI Steam
3phase Voltage
208
230
460
Pump Motor
43.6 41.2
20.6
Control Circuit
2.0
2.0
2.0
Total Running Current
45.6
43.2
22.6
Exhaust
fan
(Opt.)
2.0 2.0 1.0
Electrical Supply to the machine should exceed the figures by the amount required by
local codes.
Note: Changing the voltage of the machine in the field requires different heating
elements.
Contact the factory if this situation arises.