beautypg.com

Electrical data for models sw‐48‐ri electric, Electrical data for models sw‐48‐ri gas, Electrical data for models sw‐48‐ri steam – Insinger SW-48-RI User Manual

Page 7

background image

 

 

 

 

DOC SW‐48‐RI 2.2010                                                                                               

www.insingermachine.com

 

 
 

 

 

 

ELECTRICAL DATA for MODELS SW‐48‐RI Electric  

3phase Voltage

208

230

460

Pump Motor

43.6

41.2

20.6

Control Circuit

2.0

2.0

2.0

Wash Heater (one 9kW + one 4.5 kW)

39.5

35.9

18.9

Rinse Heater (two 9kW)

50.0

45.2

22.6

Total Running Current

133.1

122.3

62.1


Exhaust

fan

(Opt.)

2.0 2.0 1.0

ELECTRICAL DATA for MODELS SW‐48‐RI Gas  

3phase Voltage

208

230

460

Pump Motor

43.6

41.2

20.6

Control Circuit

2.0

2.0

2.0

Rinse Heater (two 9kW)

50.0

45.2

22.6

Total Running Current

95.6

88.4

45.2


Exhaust

fan

(Opt.)

2.0 2.0 1.0

ELECTRICAL DATA for MODELS SW‐48‐RI Steam  

3phase Voltage

208

230

460

Pump Motor

43.6 41.2

20.6

Control Circuit

2.0

2.0

2.0

Total Running Current

45.6

43.2

22.6


Exhaust

fan

(Opt.)

2.0 2.0 1.0

Electrical Supply to the machine should exceed the figures by the amount required by
local codes.

Note: Changing the voltage of the machine in the field requires different heating

elements.

Contact the factory if this situation arises.