Sw48ri specifications – Insinger SW-48-RI User Manual
Page 6
6
DOC SW‐48‐RI 2.2010
www.insingermachine.com
SW48RI SPECIFICATIONS
OVERALL DIMENSIONS
WIDTH = 57” (60” WITH SIDE SUPPORT ANGLES)
DEPTH = 65”
HEIGHT (OVERALL) = 92‐1/2” (94‐1/2” GAS)
HEIGHT (PIT MODEL) = 81‐1/2” ABOVE FLOOR
HOT WATER SYSTEM
1” HOT WATER SUPPLY REQUIRED, UNION PROVIDED
140° F. WATER REQUIRED AT THE MACHINE
168 GPH AT 20 PSI (14 GAL./CYCLE x 12 CYCLES/HR.)
RINSE BOOSTER: TWO 9 kW HEATING ELEMENTS IN A 20 GAL. RINSE TANK
FULL LOAD AMPS
208 VOLT
230 VOLT
460 VOLT
ELECTRIC
133.1
122.3
62.1
GAS/STEAM (INJECTED)
95.6
88.4
45.2
STEAM (RECIRCULATING)
45.6
43.2
22.6
GAS SYSTEM (GAS MACHINES ONLY)
½” GAS SUPPLY
NATURAL: 7” W.C. MINIMUM INLET, 6” W.C. MAIN MANIFOLD = 66,000 BTU
PROPANE: 11” W.C. MINIMUM INLET, 10” W.C. MAIN MANIFOLD =66,000 BTU
4” STAINLESS STEEL CHIMNEY ON BACK OF MACHINE
STEAM SYSTEM (STEAM MODELS ONLY)
¾” STEAM LINE, 10 to 15 PSI –
37 LBS. PER HOUR AVERAGE ELECTRIC HEATED RINSE
76 LBS. PER HOUR AVERAGE STEAM HEATED RINSE
WASH SYSTEM
10 HP & 5 HP PUMPS IN SERIES RECIRCULATES APPROXIMATELY 240 GPM @ 60 PSI
HEAT: >
ELECTRIC – ONE 9 kW AND ONE 4.5 Kw HEATING ELEMENT
>GAS – THREE 22,000 BTU RATED INFRARED BURNERS = 66,000 BTU
>STEAM – DIRECT INJECTION, 10 to 15 PSI, 37 LBS. PER HOUR AVERAGE
RECIRCULATED, 10 to 15 PSI, 76 LBS. PER HOUR AVERAGE
65 GALLON WASH TANK
1-1/2” COPPER DRAIN
8” STEAM EXHAUST VENT COMPANION FLANGE
(REQUIRES PVC, CPVC, OR STAINLESS STEEL FIELD INSTALLED DUCT)