Insinger Commander 18-6 User Manual
Page 18

DoorTypeTM2013
www.insingermachine.com 800-344-4802
16
CLEANING PROCEDURES (continued)
5. Clean suction strainers of build-up.
PRESSURE ADJUSTMENT
Pressure in the final rinse must be maintained at 20
± 2 psi. Adjustment of the pressure is made with the
adjusting screw on the pressure reducing valve.
NOTE:
Improper cleaning of the suction strainers
will cause the pumps to cavitate. This will
cause poor washing results.
6. Clean the tank level float with a plastic abrasive pad (do
not use steel wool).
CAUTION:
Level floats must be cleaned daily.
Build-up of grease and dirt will cause faulty operation
of the tank fill heating system.
NOTE:
Upper and lower wash & rinse pipes are
not the same.
7. Final rinse nozzles should be cleaned of matter clogging
the jet spray.
8. The doors should be left open to allow drying of interior
surfaces.
If there are flow or pressure problems with the pressure
reducing valve, CAREFULLY remove the strainer
assembly and clean the strainer screen. Be careful
not to damage the Hex nut o-ring
NOTE:
The pressure reducing valve is supplied
only on units equipped with optional booster
PART 3 OPERATION & CLEANING INSTRUCTIONS
®