Appendix B: Rack Mount Options
CWDM MUX/DEMUX units can be mounted in a 19” rack using the mounting kit
Mounting Instruction Rackmount-Kit 455-8G
Using the Rackmount-Kit 455-8G, up to 4 devices of the device size 103x143x42mm (Dual-
Head Devices) can be mounted into a 19“-Server Rack. The Rackmount Kit requires 1U Rack
space. Blind plates (in the list of parts delivered) allow covering unused device positions.
Rackmount-Kit 455-8G – List of parts delivered:
The CWDM MUX/DEMUX units require the rack space of two regular
devices. So far you can mount up to 2 CWDM MUX/DEMUX units into a
1U rack space.
Mounting instruction:
•
Align the holes on the base plate with the vacant screw holes on the base of the device.
•
Fasten the base of the unit to the plate of the mounting kit
Only use the supplied, short screws, to prevent damages on
the PCB’s
•
Close the remaining gaps with blanking plates.
base plate
8 pieces spacer – M2,5x2
8 pieces M2,5x5 Philips type
countersunk screws
3 pieces blind plate