beautypg.com

5 rj45 (interconnect), 6 fiber sfp type lc (interconnect), 7 serial interface – IHSE USA 481 Series Draco vario HDMI User Manual

Page 62: 5 rj45, Interconnect), 6 fiber, Type, Lc (interconnect), 7 serial, Interface

background image

Draco KVM Extender

62

2013-08-13

7.1.5

RJ45 (Interconnect)

The communication of the Cat X devices requires a 1000BASE-T
connection.

Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with
RJ45 connectors at both ends. All four cable wire pairs are used.


Pos: 86 /806-IHSE/Technische Daten/Schnittstellen/Glasfaser SFP Typ LC @ 5\mod_1278937700855_6.doc @ 43149 @ 3 @ 1

7.1.6 Fiber SFP Type LC (Interconnect)

The communication of fiber devices is performed via Gigabit SFPs that
have to be connected to suitable fibers fitted with connectors type LC ().

The correct function of the device can only be guaranteed with SFPs
provided by the manufacturer.


SFP modules can be damaged by electrostatic discharge (ESD).

Please consider ESD handling specifications.


Pos: 87 /806-IHSE/Technische Daten/Schnittstellen/Serielle Schnittstelle @ 5\mod_1291127444390_6.doc @ 44828 @ 3 @ 1

7.1.7 Serial Interface

The serial interface option supports a

full-duplex transmission

with a real

hardware handshake up to a Baud rate of 115,200 Baud.

The CON Unit is cabled as DTE (Data Terminal Equipment, like CPU
output) and can be connected directly to DCE devices (Data
Communication Equipment).

A touch screen can be connected directly to the CON Unit.

To connect to a serial printer (or any other DTE instead of DCE
device), you need a null modem cable (crossed cable) between CON
Unit and the device.

Operation of several devices:

The serial interface transmits 6 signals (3 for each direction).

Normally,

4 of the 6 signals are handshake signals (in addition to RxD and TxD).

The following configurations, however, can be realized using special
adapter splitting cables:

Three single 2-wire transmissions

Two transmissions with a handshake signal

A serial mouse and a single 2-wire transmission.