beautypg.com

Draco kvm extender 58 – IHSE USA 481 Series Draco vario HDMI User Manual

Page 58

background image

Draco KVM Extender

58

2013-08-13

In order to configure a redundant CPU Unit for the operation with two
parallely controlling CON Units, proceed as follows:

1. Connect a redundant CPU Unit to any source (computer, CPU) by

using a mini USB connection.

2. Open the file "Config.txt" that is located on the appearing flash drive

of the extender.

3. In order to activate the function of taking over control by keyboard,

write the parameter KBDCON into the second line of the file.
In order to activate the function of taking over control by mouse, write
the parameter MOUCON into the second line of the file.
In order to activate the function of taking over control by keyboard and
mouse, write the parameters in the second and third line with one
parameter per line.

4. Activate the release timer by writing the parameter RELEASETIME=n

into the next free line. The variable "n" defines the time in seconds
and has to be replaced by the numbers 0 to 9 (e.g.
RELEASETIME=5).
If this parameter is not activated at all, the release time is set to
10 seconds by default.

5. Save

your

changes.

6. Reboot the CPU Unit.

Example View – Config.txt

When using redundant CPU Units in combination with a KVM matrix, the
function of the competing control will be automatically deactivated in the
extender and will have to be performed by the KVM matrix.

Pos: 78 /806-IHSE/Betrieb/KVM-Schaltung/481-xx Lokale KVM-Umschaltung @ 9\mod_1369724748986_6.doc @ 72081 @ 2 @ 4