beautypg.com

Figure 1-4, Typical dc lifter wiring -5, Installation - to cutting machine & torch lifter – Hypertherm THC2 Torch Height Control User Manual

Page 13: Thc-2 torch height control, Page 1-5

background image

THC-2 Torch Height Control

Page 1-5

INSTALLATION - To Cutting Machine & Torch Lifter

UP

DOWN

DOWN

UP

MAN

AUTO

AUTO

MAN

DN

DN

UP

UP

Lifter

Motor

DC

Power

+

_

UP

115VAC

DN

115VAC

JUMPER

1TB-133

1TB-131

1TB-132

Jump to wire 106
on DC Power Supply
1PS in THC-2

Jump to wire 107
on DC Power Supply
1PS in THC-2

Add jumper and relays to THC-2

Quantity (2), 2 pole, N/O relays,
115 VAC coils - Mount in the THC-2

Double pole, single throw
toggle switch - Mount in
operator station

Figure 1-4 Typical DC Lifter Wiring