MAINTENANCE

3-9

powermax

600

Service Manual

TROUBLESHOOTING

The complexity of the circuits require that service technicians have a working knowledge of inverter
power supply theory. In addition to being technically qualified, technicians must perform all testing
with safety in mind.

If questions or problems arise during servicing, call the Hypertherm Technical Services Department
at the phone numbers listed in the front of this manual.

Test Equipment

Multimeter

Troubleshooting Procedures and Sequence

Refer to the system wiring diagram when performing the
troubleshooting procedures.

To locate power supply components refer to Section 4.
Refer to Section 5 for torch components.

After the problem has been located and repaired, refer
to the

Sequence of Operation flow diagram in this

section to test the power supply for proper operation.

Visual Inspection

External

Visual Inspection

Internal

Power OFF &
Disconnected

Resistance Checks

Power ON

Troubleshooting

Guide

Voltage Checks

Visual Inspection - External

1. Inspect the outside of the power supply for damage to the cover and external components.

2. Inspect the torch and the torch lead for damage.