beautypg.com

Powermax, Maintenance, Service manual – Hypertherm Powermax600 Service Manua User Manual

Page 28: Controls and indicators

background image

3-2

MAINTENANCE

powermax

600

Service Manual

PMX600.05

ON

OFF

Pressure
Gauge

Current

Adjustment

Knob

Pressure
Regulator

ON (I)/OFF (0)
Switch

Figure 3-1 Powermax600 Controls

Controls - See Figure 3-1.

Green POWER IS ON
When illuminated, indicates that AC voltage is supplied to the power supply
and that the ON/OFF switch is in the ON position.

Green SYSTEM READY

When illuminated, indicates that circuits are activated and that all fault
conditions are clear (none of the yellow lamps are illuminated).

Yellow LOW LINE VOLTAGE

When illuminated, indicates that the AC line voltage is: 1) below operating
limits ,or 2) is missing 1 phase (230V and 400V systems only).

Yellow LOW GAS PRESSURE

When illuminated, indicates that the incoming gas pressure is below operat-
ing limits.

Yellow TORCH PARTS ARE LOOSE OR REMOVED

When illuminated, indicates that the torch consumables are loose or not
installed.

Yellow HIGH TEMPERATURE

When illuminated, indicates that the power supply temperature has ex-
ceeded operating limits.

CONTROLS AND INDICATORS

Indicator Lamps

Pilot Arc

Control Switch

(208-240, 480V)

11-99