1
HT4001 Power Supply with H401 Slave
Maximum OCV (U
0
) ............................................. 400 VDC
Maximum Output Current (I
2
) .............................. 760 A
Output Voltage (U
2
) ............................................. 80-200 VDC
Duty Cycle Rating (X) .......................................... 100% @ 40
°C at 760 A and 200 V
Ambient Temperatures/Duty Cycle ..................... Power supplies will operate between +14
°
and 104
°F (-10° and +40°C).
Power supplies operated in an ambient
temperature above 86
°F (30°C) may show
some decrease in duty cycle.
Cooling ................................................................ Forced Air (Class F)
2
H401 Slave Power Supply
(used when cutting with over 400 amps)
Dimensions and Weight:
Width ................................................................... 40" (1025 mm)
Height .................................................................. 53" (1345 mm)
Depth ................................................................... 50" (1270 mm)
Weight ................................................................. 2250 pounds (1022 kg)
4
Timer/Counter
Dimensions and Weight:
Width ................................................................... 6-1/2" (165 mm)
Height .................................................................. 2-1/2" (64 mm)
Depth ................................................................... 8-5/8" (22 cm)
Weight ................................................................. 3 pounds (1 kg)
Figure 2-2 Timer/Counter Dimensions
1.70"
6.25"
8.50"
.50"
5/32"
dia. (4)
6.50"
3.38"
4-00