TROUBLESHOOTING

ELECTRICAL SYSTEM:

SITUATION

CAUSES

REMEDY

Starter will not
turn engine over

Circuit breaker engaged

Push button to reset Consult
your dealer for repair

Starter will not
turn engine over

Dead battery

Charge battery

Battery discharge

Poor connections on
battery Battery water
low Wrong battery
installed in mower

Tighten or replace as required

Battery discharge

Engine electrical system
not functioning correctly

Have electrical system checked by

your dealer

Battery discharge

Engine being operated

at too low an RPM

Increase engine RPM Contact your

dealer for information

NOTE: Electrical system failures are generally simple in nature, always check the obvious

first and then move onto the more complicated parts used. Poor battery service,
loose connections, corrosion, frayed or broken wiring, are more likely than component
failure.