OWNER’S MANUAL

For more information, visit www.desatech.com

WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

INSTALLATION

WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP gas, do not install heater.
Call dealer where you bought heater for
proper type heater.

IMPORTANT:

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

CLEARANCES TO
COMBUSTIBLES

(Vent-Free Operation Only)

WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining side
and back walls.

Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor.

IMPORTANT:

You

must maintain minimum wall and ceiling
clearances during installation. The mini-
mum clearances are shown in Figure 4.
Measure from outermost point of stove top.

Minimum Wall and Ceiling
Clearances (see Figure 4)

A. Clearances from outermost point of

stove top to any combustible side wall
should not be less than 12 inches.

B. Clearances from outermost point of

stove top to any combustible back wall
should not be less than 6 inches (In-
cludes corner installations).

C. Clearances from the stove top to the

ceiling should not be less than 48
inches.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Figure 4 - Minimum Clearance to Walls and Ceiling

Front View

Top View

Side View

Front of

Stove Unit

Continued

Back Wall

Side Wall

Side Wall

12

"

Minimum

12

"

Minimum

6

"

Minimum

6"

Minimum

48"

Minimum

Ceiling

Floor

Back Wall

Corner

Wall

Wall

6

"

Minimum

6

"

Minimum

12"

Minimum

12"

Minimum

48"

Minimum