beautypg.com

Vent-free propane/lp pedestal stove, Operating heater, Inspecting burners – Desa S39PT User Manual

Page 14: Continued

background image

14

107435

VENT-FREE PROPANE/LP PEDESTAL STOVE

For more information, visit www.desatech.com

Figure 23 - Pilot

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps

3 through 7, pages 13 and 14. This
heater has a safety interlock system.
Wait one (1) minute for system to
reset before lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

to desired heating level. The

burners should light. Set control knob
to any heat level between HI and LO.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise

Clockwise

to

the OFF position.

Shutting Off Burners Only (pilot
stays lit)

Turn control knob clockwise

Clockwise

to

the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the heat
output and flame height from higher to
lower settings, or pilot, in order to maintain
the comfort level you select. The ideal com-
fort setting will vary by household depend-
ing upon the amount of space to be heated,
the output of the central heating system, etc.

OPERATING
HEATER

Continued

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat-
tern. Figure 25 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 25

• turn heater off (see To Turn Off Gas to

Appliance)

• see Troubleshooting, pages 16 through 18

Figure 24 - Correct Pilot Flame Pattern

Figure 25 - Incorrect Pilot Flame Pattern

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Thermocouple

Pilot Burner

Light your gas appliance with the blower
off. Turn the blower on to deliver heated
air at the top louvers. The blower fea-
tures a variable control which allows you
to select the speed you desire.

If using the GA3650TA Blower Accessory:

In the ON position, the blower will start
when the thermostat senses a sufficient
increase in firebox temperature (approxi-
mately 10 to 20 minutes depending on
heat setting).

Note:

Your gas stove and

thermostat blower will not turn on and
off at the same time. The stove may run
for several minutes before the blower
turns on. After the heater modulates to
the pilot position, the blower will con-
tinue to run. The blower will shut off
after the firebox temperature decreases.

Note:

It is safe to operate stove with

blower turned off. However, the blower
helps distribute heated air from the stove.

Note:

Periodically check the louvers of

the firebox and remove any dust, dirt, or
other obstructions.

OPERATING

OPTIONAL BLOWER

ACCESSORY

1.

Follow steps 1 through 5 under Light-
ing Instructions,
page 13.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 in column 1.

MANUAL LIGHTING

PROCEDURE

Note:

Selecting the Hi setting with the

control knob will cause the burners to
remain fully on, without modulating down
in most cases.

Continued