beautypg.com

Vent-free propane/lp pedestal stove, Installation, Continued – Desa S39PT User Manual

Page 12

background image

12

107435

VENT-FREE PROPANE/LP PEDESTAL STOVE

For more information, visit www.desatech.com

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

INSTALLATION

Continued

Power
Cord

Speed Control
Housing

Control
Knob

Figure 21 - Connecting Switch, Blower,
and Speed Control Wires

120 Vac. 60 Hz. 90 Amps
DESA International, Bowling Green, KY

WARNING: Never attempt to service heater while it

is plugged in, operating, or hot. Burns and electrical
shock could result. Only a qualified service person
should service or repair heater.

If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105

°

C wire or it’s equivalent.

WARNING: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper opera-
tion after servicing.

Wiring
Diagram
Decal

Figure 19 - Attaching Wire Harness to
Thermostatic Switch and Cover Assembly

Thermostatic
Switch
Mounted to
Cover

Wire Harness

Lower Hole

Figure 20 - Assembling Thermostatic
Switch and Cover to Firebox Back Panel

Thermostatic
Switch
Mounted to
Cover

Wire Harness

Hole in Firebox
Back Panel

Screws

Wire Harness

Blower

Red
Switch
Wire

Green
Ground
Wire

Ground
Wire Screw

White Speed
Control Wire

Black
Speed
Control
Wire

Blue
Switch
Wire

11. Remove three screws and cover plate

from center of firebox back panel.
Keep screws but discard cover plate
(see Figure 18).

12. Locate thermostatic switch/cover plate

assembly and wire harness supplied
with blower. Attach wire harness ter-
minals to terminals on thermostatic
switch. Push firmly. Make sure the bot-
tom hole of cover is on the opposite side
from the wire harness (see Figure 19).

13. Feed terminal ends of wire harness into

the hole in firebox back panel from
front of firebox. Pull the ends of the
harness to the top of firebox near
blower (see Figure 20).

14. Align holes in the switch/cover assem-

bly with holes in firebox back panel.
Using 3 screws from step 11, attach
assembly to firebox back panel. Tighten
screws firmly (see Figure 20).

15. Working from the rear of the stove,

place entire power cord, including
speed control housing, in lower control
compartment (see Figure 21).

Figure 18 - Removing Cover Plate

Cover
Plate

Firebox Back Panel

Screws

16. Route ends of 3-wire power cord up from

the lower control compartment through
the plastic bushing, then up to the upper
cavity of stove (see Figure 21).

17. Connect white wire from speed control

to either terminal on blower motor (see
Figure 21). Push firmly.

18. Connect the black wire from speed con-

trol to blue wire on switch/cover assem-
bly (see Figure 21).

19. Connect red wire from switch/cover

assembly to remaining terminal on
blower motor (see Figure 21). Push
firmly.

20. Attach green wire from speed control

to front tab of blower housing using
screw provided (see Figure 21). Tighten
securely.

21. Using the four screws previously re-

moved, mount blower assembly to
stove by reattaching blower brackets to
rear panel (see Figure 15, page 10).
Tighten screws securely.

22. Install plastic control knob onto output

shaft of speed control housing (see Fig-
ure 21). Place speed control housing just
inside control compartment door in front
of stove (see Figure 17, page 11).

23. Using two screws provided in blower

kit, mount blower speed control hous-
ing to mounting tab in left side of lower
control compartment (see Figure 17,
page 11).

24. Check to make sure that the power cord is

completely clear of blower wheel and there
are no foreign objects in blower wheel.

25. Carefully replace stove top panel. Align

holes and replace six screws removed
in step 1, page 10. Slide top trim over
tip panel. Attach with 2 screws removed
in step 1, page 11.