beautypg.com

Guralp Systems CMG-3EX-EAM User Manual

Page 9

background image

Operator's Guide

So the sequence of symbols 

indicates the the green

LED is off for a long period of time (5 segments) then flashes twice.

LED sequence

Description of status

Red: 

Green: 

Sensor is locked or powered off and no
automatic functions are selected.

Red: 

Green: 

Only auto-centre is enabled.

Red: 

Green: 

Only auto-lock is enabled.

Red: 

Green: 

Both auto-lock and auto-centre are enabled.

Red: 

Green:



Sensor is centred: auto-lock and auto-centre
are both disabled.

Red: 

Green:



Sensor is centred and only auto-centre is

enabled.

Red: 

Green:



Sensor is centred and only auto-lock is
enabled.

Red: 

Green:



Sensor is centred and both auto-lock and

auto-centre are enabled.

Red: 

Green: 

Sensor is locking.

Red: 

Green: 

Sensor is unlocking

Red: 

Green: 

Sensor is centring

Red: 

Green:

Power failure waiting for auto-lock delay to

time out (alternating red/green flashes).

Red:



Green: 

Catastrophic failure the sensor has a fault
that has made it impossible to complete the

last operation.

Red: 

Green: 

Locking system limit switch fault.

Red: 

Green: 

Horizontal tilt base limit. This could be a

result of a poorly levelled sensor.

Red: 

Green: 

The current operation timed out. This could
indicate a fault or, in the case of centring, the

sensor may need to be re-centred.