7
OPERATION
= “STOP” - This overrides all other controls and when activated will apply regenerative
braking to the motor to bring it to a dead stop, and will disallow any further operation of
the motor whenever it is in this state.
= “RUN” - This removes the “STOP” command and allows the control to assume an
operational status.
= “FORWARD” - When the switch is in this position, the control will drive the motor in the
Forward direction.
= “NEUTRAL” - When the switch is in this position, the control will not drive the motor in
either direction.
= “REVERSE” - When the switch is in this position, the control will drive the motor in the
Reverse direction.
= “VARIABLE SPEED CONTROL” - By turning the rotary encoder knob in a clockwise
direction, the motor speed will be increased. When rotated in the counter-clockwise
direction, the motor speed will decrease.
= “POWER ON” - When the switch is in this position, power is supplied to the carriage
control system.
= “POWER OFF” - When the switch is in this position, power is not supplied to the
carriage control system. Note: The supply must be isolated elsewhere before removing
any covers from this equipment