Groth 8391B User Manual
Page 9
![background image](https://www.manualsdir.com/files/788260/content/doc009.png)
8
3. Pilot gas supply shutoff or low pilot gas supply pressure.
4. Restriction in pilot gas supply line or inspirator air intake. Inspirating venturi nozzle is factory drilled according to
the pilot gas pressure specified on order. Strainer or filter cartridge may be plugged; clean or replace as
required.
5. Ignition component failure:
a. Electrode shorting to ground
b. Spark disc failure
c. Transformer failure
d. Poor electrical connection between transformer and electrode
e. Failure of relay which powers ignition transformer
f.
Carbon/soot build-up on ignition electrode tip
6. Utilize the “Push-to-test” capability of the panel lamps to check the condition of the bulbs.
TABLE 4
BOLT TORQUE
MAIN BURNER FLANGE
(1)
BOLT SIZE
BOLT TORQUE
[Ft. - Lb.]
5/8" - 11 UNC
110
3/4" - 10 UNC
200
7/8" - 9 UNC
320
(1)
It is assumed that studs and nuts are
plated and torqued without lubricants.
TABLE 5
RECOMMENDED SPARE PARTS
(1)
QTY
PART
NUMBER
DESCRIPTION
1
604003900
Transformer, Ignition
1
IEA8391
Electrode, Ignition
(2)
1
604004100
Insulated Connector
1
604004200
Wire, Ignition
1
TCP839101S0
Thermocouple, pilot
1
OSP839154XX
Orifice Spud
(3)
2
347320X51
Pressure Gauge
(3)
1
3574000F2
Y-Strainer
1
604003500
Filter, Cartridge
1
359400001
Valve, Solenoid
1
112000500
Temperature
controller
(1)
When ordering, specify pilot gas and supply
pressure.
(2)
Damaged electrodes may be returned to
Groth Corporation for a complete rebuild.
Spare parts are also available for electrode
repair.
(3)
P/N may vary, please specify pilot gas and
supply pressure for proper sizing.