Greenheck SP-C50 User Manual

Read and save these instructions, Model sp-c50 ceiling/wall ventilating fan, Installation

background image

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have

questions, contact the manufacturer at the address or telephone number
listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and

lock the service disconnecting means to prevent power from being

switched on accidentally. When the service disconnecting means cannot

be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authori-
ties.

WARNING

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring

and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. This unit may be used over a tub or shower enclosure when installed in

a GFCI protected branch circuit.

8. If this unit is to be installed over a tub or shower, it must be marked as

appropriate for the application.

9. Never place a switch where it can be reached from a tub or shower.

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION

1. For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced impel-

lers, keep drywall spray, construction dust, etc. off power unit.

3. Please read specification label on product for further information and

requirements.

CAUTION

SCREWDRIVER

SLOT

WIRING

COVER

HOUSING

FLAP

1. Remove motor plate from housing by pushing down on rib in

plate while pulling out on side of housing. Motor plate may also
be removed by inserting a straight-blade screwdriver into slot
in housing and twisting screwdriver.

2. Remove wiring cover from housing by pulling straight out. Unit

is shipped ready to wire through the top of housing. To wire
through the side, bend housing flap to cover top hole and
expose side hole. DO NOT BREAK OFF FLAP. If flap breaks,
plug unused hole using standard electrical hole plug.

3. Turn off electrical power at service entrance and connect

power cable to housing using appropriate connector. Wire
black to black, white to white, and green to green or bare wire.

Push all wiring up into corner of unit and replace wiring cover.
Make sure cover holds housing flap in place against side or
top of housing. CAUTION: DO NOT ALLOW WIRES TO
EXTEND OUTSIDE OF WIRING BOX. Wire left exposed will
become pinched or cut when motor plate is installed.
Electrical shock may result.

TABS

TABS

4. Choose the location for your fan. For best performance, use the

shortest possible duct run and a minimum number of elbows.
For wall installations: Position unit so damper flap closes when
unit is off.

MAKE SURE HOUSING
WILL BE FLUSH WITH FIN-
ISHED CEILING OR WALL.
Slotted tabs are provided to
locate housing flush with
1/2" ceiling or wall material.
Bend tabs outward 90

0

(use

a screwdriver if desired) and
position housing so that tabs
rest against bottom edge of
joists (or front of stud). Nail
housing to joist or stud using four nails to ensure a solid, quiet
installation. Ceiling installations: Tabs on opposite side of
housing can be bent outward to rest on top of 1/2" ceiling material
and provide extra stability.

5

. New installation prior to finishing the ceiling or wall:

MODEL SP-C50

CEILING/WALL VENTILATING FAN

120 VAC LINE IN

BLACK

BLACK

GROUND

WHITE TO

WHITE

SWITCH OR TIMER

GREEN TO

GREEN OR

BARE WIRE

SWITCH BOX

RECEPTACLE

WHITE TO

WHITE

BLACK TO

BLACK