counterbalance adjustment instructions cont...
5. Open damper and recheck full open operation.
Readjust per step 3 if necessary. Recheck full closed
position (step 4) as any modification at one position
has a slight impact on the other.
6. Tighten all counterweight and arm fasteners securely.
component
applicable
Model
galvanized
Part number
Stainless
Part number
Axle Adapter, 3/8” to 3/4”
square OD
HB-110, HB-120
370120
416343
3/4” Crankarm
All
652982
687738
3/8”-16x2 Crankarm Bolt
All
415882
415924
3/8”-16 Hex Nut for
Crankarm
All
415457
415799
Short Counterweight Arm
(81/2 in. )
All
657344
689404
Long Counterweight Arm
(121/2 in. )
All
657343
683951
3/8”-16 set screw for
short/long arm
All
415050
415763
3/8” -16 Weldnut/Hex nut
for short/long arm
All
415127
415799
Counterweight plate,
21/2” x 31/2”
All
653143
687636
Counterweight plate,
31/2” x 31/2”
All
653142
687635
1/4”-20 Serrated Flange Nut
All
415455
415575
1/4”-20 x 3/4” Bolt
All
415490
415573
1/4”-20 x 11/4” bolt/
11/2” bolt
All
415973
416103
Standard components
7. Test damper closure by opening damper blades and
releasing from 1/4, 1/2, 3/4 and full open position.
Damper should close from all positions without
assistance.
469620• HB Series Rev. 2, October 2012
Copyright 2012 © Greenheck Fan Corporation
As a result of our commitment to continuous improvement, Greenheck reserves the right to change
specifications without notice.
Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in
the Library under Warranties.
®
Phone: (715) 359-6171 • Fax: (715) 355-2399 • E-mail: [email protected] • Website: www.greenheck.com
Our Commitment