Regulator will
not shut off air
outlet.

Damaged regulator

Replace

PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1. Check fuse box for blown

fuse and replace as

necessary. Reset circuit

breaker. Do not use a fuse

or circuit breaker with

higher rating than that

specified for your particular

branch circuit.

2. Check for proper fuse. You

should use a time delay

fuse.

3. Check for low voltage

conditions and/or proper

extension cord.

4. Disconnect the other

electrical appliances from

circuit or operate the

compressor on its own

branch circuit.

Motor overload protection
switch has tripped

Let motor cool off and

overload switch will

automatically reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically

when tank pressure drops

below "cut-in" pressure of

pressure switch.

Extension cord is wrong
length or gauge.

Check for proper gauge wire
and cord length.

Loose electrical connections. Check wiring connection

inside pressure switch and
terminal box area.
Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or
replace.

Possible defective motor or
starting capacitor.

Have checked by a Trained

Service Technician. Do not

operate the compressor in

the paint spray area. See

flammable vapor warning.

Paint spray on internal motor
parts.

Bleed the line by pushing the

lever on the pressure switch

to the "off" position; if the

valve does not open, replace

switch.

Pressure release valve on
pressure switch has not
unloaded head pressure.