How to Start:

1. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build.

Motor will stop when tank pressure reaches "cut-out" pressure.

2. Turn regulator knob clockwise to increase pressure and stop when desired

pressure is reached. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of
gasoline or other combustible vapors. If the compressor is being used to
operate a sprayer DO NOT place near the spray area.

Before Each Start-Up:

1. Place On/Auto/Off lever to "OFF".
2. Turn the regulator knob counterclockwise to set the outlet pressure to zero.
3. Attach hose and accessories.

NOTE: The hose or accessory will require a

quick connect plug if the air outlet is equipped with a quick connect.

Too much air pressure causes a hazardous risk of

bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must

never exceed the maximum pressure rating.

MAINTENANCE

Customer Responsibilities

Daily

or after

each

use

Before
each
use

Yearly

●1

1- more frequent in dusty or humid conditions

Check Safety Valve
Drain Tank

Air Filter

Unit cycles automatically when power is on. When

performing maintenance, you may be exposed to voltage

sources, compressed air, or moving parts. Personal injuries can occur.

Before performing any maintenance or repair, disconnect power source

from the compressor and bleed off all air pressure.

Air compressor pump intake
and exhaust valves

Frequently