beautypg.com

Troubleshooting – Delta 66-651-1 User Manual

Page 19

background image

19- ENG

A08184

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving

parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting

any repairs, unplug the air compressor and bleed off all air tank air

pressure.

PROBLEM

CAUSE

CORRECTION

Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.

Pressure switch "cut-out"
too high.

Move On/Auto/Off lever
to the "OFF" position, if
the outfit does not shut off
contact a Trained Service
Technician.

Contact a Trained Service
Technician.

Excessive tank
pressure - safety
valve pops off.

Tube fittings are not tight
enough.

Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution.

Do Not

Overtighten.

Air leaks at
fittings.

Air leaks at
pressure switch
release valve.

Defective pressure switch
release valve.

Contact a Trained Service
Technician.

Air leaks in air
tank or at air
tank welds.

Defective air tank.

Air tank must be replaced.
Do not repair the leak.

Do not
drill into,

weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.

Air leaks
between head
and valve plate.

Leaking seal.

Air leaks at or
inside check
valve

Check valve seat damaged.

A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Replace check
valve. Refer to the "To
Replace or Clean Check
Valve" in the "Service and
Adjustment" section.

Contact a Trained Service
Technician.