beautypg.com

Delta 66-651-1 User Manual

Page 17

background image

17- ENG

A08184

8. Apply sealant to the check valve threads. Reinstall the check valve (turn

clockwise).

9. Replace the pressure release tube. Tighten nuts.
10. Replace the outlet tube and tighten nuts.
11. Perform the Break-in Procedure. See "Break-in Procedure" in the

Operation section.

To Replace Regulator

1. Release all air pressure from air tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug compressor.
3. Remove the outlet pressure gauge and quick connect (if equipped) from

the regulator.

4. Remove the regulator.
5. Apply pipe sealant tape to the nipple.

6. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air

flow.

7. Reapply pipe sealant to outlet pressure gauge and quick connect.
8. Reassemble outlet pressure gauge and quick connect. Orient outlet

pressure gauge to read correctly. Tighten quick connect with wrench.

Nipple

Outlet

Pressure

Gauge

Regulator

Regulator

Quick

Connect

Arrow

Regulator