42
Technical data
Electrical data in-
put 230V
Standards 230V
Electrical data in-
put 120 V
Standards 120V
Mains voltage
~ 230 V AC, +/- 15 %
Mains frequency
50 / 60 Hz
Mains current
max. 9 A eff.
Mains fuse protection
max. 16 A
Efficiency
max. 96 %
Effective power
max. 1120 W
Power consumption (standby)
max. 2.4 W
Protection class
I (with PE conductor)
Maximum permitted mains impedance at the interface
(PCC) to the public grid
None
EMC emission class
A
Marks of conformity
CE
IEC 60068-2-6
Sine oscillations (10 - 150 Hz; 1.5 h / axis)
IEC 60068-2-29
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-1
EN 60335-2-29
EN 61000-6-2
EN 61000-6-3
(Class A)
EN 62233
EMF Standard
Mains voltage
~ 120 V AC ±15%
Mains frequency
50/60 Hz
Mains current
max. 16 A eff.
Mains fuse
max. 20 A
Efficiency
max. 94.5%
Effective power
max. 1120 W
No-load power consumption
max. 7.8 W
Protection class (with ground conductor)
I
Maximum permitted mains impedance at the interface
(PCC) to the public grid
none
Mark of conformity
cTÜVus
EMC device class
A
UL1236
C22.2 No 107.1-01
FCC CFR 47 Part 15
(Class A)