Synergic lines – Fronius Acctiva Professional 35A User Manual
Page 39

37
EN
Synergic lines
Safety
Available charac-
teristics
Charging characteristic IUoU:
I
1
= Main charging current
U
1
= Final charging voltage
U
2
= Conservation charging voltage
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Follow the battery manufacturer's instructions. The battery must not be
connected to the charger when setting parameters.
Operating mode Battery Charac-
teristic
I
1
U
1
[6/12/24V] I
2
U
2
[6/12/24V] Ex.
Charging
WET
IUoU
35* 7.2/14.4/28.2
-
6.75/13.5/27
Yes
AGM
6.84/13.68/
27.36
GEL
7.05/14.1/28.2
USER
2-30
1.9-29.9
Buffering (Trickle)
mode
All
IU
35
6.75/13.5/27
-
-
Yes
Refresh
WET
IUIoU
35* 7.2/14.4/28.8
4
6.75/13.5/27
No
AGM
2
6.84/13.68/
27.36
GEL
7.05/14.1/28.2
USER
IUa
35** 2-34
-
-
Yes
Power supply
mode
None
IU
35
6.75/13.5/27
-
-
Yes
Battery changing All
IU
35
6.75/13.5/27
-
-
No
I
1
Main charging current [A]
maximum device current: 35 A
*
20 A per 100 Ah of specified battery capacity
**
10 A per 100 Ah of specified battery capacity
U
1
Final charging voltage [V]
I
2
Recharging current [A per 100 Ah of specified battery capacity]
U
2
Conservation charging voltage [V]
Automatic switchover to pulse charge conservation after 12 hours, apart
from user application in Expert mode
Ex.
Adjustable final charging voltage and conservation charging voltage in Ex-
pert mode. For trained professionals only
I
1
U
1
U
2