Technical data – Fronius Acctiva Easy User Manual
Page 34

32
Technical data
*) The effective current corresponds to the specifications for conventional battery chargers
**) IMPORTANT! For indoor use only, do not expose the charger to rain or snow.
***) The output power may be reduced at higher temperatures (derating).
The proper functioning of the charger is tested at 5-85% humidity: climate class B
Acctiva Easy
1202
1204
1206
2403
6/12
12/24
Selectiva
1006
2003
/
1002/2003
Mains voltage [V AC]
100-240 V 100-240 V 100-240 V
240 V
240 V
Mains voltage tolerance
+/-15 %
+/-15 %
+/-15 %
+/-15 %
+/-15 %
+/-15 %
Grid frequency
50/60
Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Max. open circuit power
consumption
1.5 W
1.5 W
1.5 W
1.5 W
1.5 W
1.5 W
Nominal output
18 W
36 W
48 W
48 W
18/24 W
36/43 W
Battery voltage
[V DC]
12 V
12 V
12 V
24 V
6/12 V
12/24 V
Arithmetic charging cur-
rent
[A DC]
at 230 V
at 110 V
1.5 A
0.95 A
3.0 A
1.9 A
4.0 A
2.5 A
2.0 A
1.25 A
3.0/2.0 A
3.0/1.8 A
Effective current
[Aeff. DC]
*)
2.0 A
4.0 A
6.0 A
3.0 A
4.0/3.0 A
4.0/2.5 A
Battery capacity
Acctiva
Easy
Selectiva
1-85 Ah
1-85 Ah
2-150 Ah
2-135 Ah
3-200 Ah
3-180 Ah
1.5-100 Ah
2-100 Ah
2-135 Ah
1.5-100 Ah
2-135 Ah/
1.5-90 Ah
2-100 Ah/
1.5-85 Ah
Chargeable cells
6
6
6
1/2
3/6
6/12
Duty cycle
100%
100%
100%
100%
100%
100%
Charging characteristic
IUoU
IUoU
IUoU
IUoU
IUoU
IUoU
EMC Class
EN 61000-6-3 (Class B)
EN61000-6-1
FCC 15 Class B
Protection **)
IP30
IP30
IP30
IP30
IP30
IP30
Operating temperature
***)
-20°C to 50 °C (-4°F to 122°F)
Storage temperature
-25°C to 80°C (-13°F to 176°F)
Length of time before
safety cut-out trips
Acctiva
Easy
Selectiva
75 h
75 h
75 h
75 h
56 h
75 h
75 h
75 h
29 h
44 h
75 h
Length of time to switch
off if incorrect voltage se-
lected
10 min
10 min