Establishing con-
nection to bat-
tery/
disconnecting
Establish a connection as follows:
Unplug the charger from the mains
Plug charger lead into charger socket
Connect (+) charging terminal to positive pole (red) on battery
Connect (-) charging terminal to negative pole (black) on the battery, or to vehicle body
(e.g. engine block) in the case of vehicle power supplies.
If using an on-board or system plug to connect the charger lead, steps 3 and 4 do not apply.
Instead, connect charger cable to a suitable on-board socket.
Acctiva Easy 1202, 1204, 1206, 2403
Charging characteristic setting:
Setting A: For charging all lead acid starter batteries
Setting B: Always charge using setting B for stationary batteries
in standby applications (e.g.: emergency power systems) or in
ambient temperatures exceeding 35 °C!
Selectiva 1006, 2003
Charging characteristic setting:
Setting A: For charging all lead acid traction batteries
Setting B: Always charge using setting B for stationary batteries
in standby applications (e.g.: emergency power systems) or in
ambient temperatures exceeding 35 °C!
NOTE! Setting the selector switch incorrectly can result in the following:
-
Charger displays incorrect test results
-
Charger switches to "error"
-
Battery will not be fully charged
-
Vehicle power supply will be damaged (e.g. in back-up mode)
IMPORTANT! It is not permitted to use this charger to charge dry batteries (primary cells).
ACCTIVA EASY 1206
110-230V / 50-60Hz 48W
12V = 2,5 - 4Aarith
Out:
Art. Nr.:
In:
Chr. Nr.:
A
B
Always stop charging before you disconnect the charging cable!
Toujours arrêter la charge avant de débrancher le câble de charge!
IP
30
00007432420000
4,010,XXX,XXX
00000000000000
SELECTIVA 1006
110-230V / 50-60Hz 48W
12V = 2,5 - 4Aarith
Out:
Art. Nr.:
In:
Chr. Nr.:
Always stop charging before you disconnect the charging cable!
Toujours arrêter la charge avant de débrancher le câble de charge!
IP
30
4,010,XXX,XXX
00000000000000
00007432420000
WARNING! Risk of explosion from short circuits and arcs. Before connecting/dis-
connecting the battery, disconnect the charger from the mains supply. During op-
eration, check that charging terminals and battery poles are properly connected.
NOTE! When disconnecting, it is imperative to follow the above instructions in the
reverse order to avoid short circuits and arcs.