Fronius IG 300 User Manual
Page 44

36
2.
Fan controller ready for operation
-
Press „Enter“ key (D)
3.
Start fan controller test
-
Press „Enter“ key (D)
4a. The fan controller is tested.
-
This involves the roof fans running for
approx. 20 seconds.
4b. If a fault is detected on the fan cont-
roller or one or more roof fans:
-
„Safety / Stop“ is displayed instead of
„Test / Run“
-
A defect on a fan means that the fan
controller cannot be tested until later
-
The number „1-15“ indicates which
roof fans are defective or have no
power supply
(C)
(C)
(D)
(C)
(D)
(D)
(B)
1.
„State Fan“ ... Queries status for the
fan controller
-
Initiating „State Fan“ setting: Press
„Enter“ key (D)
(B)
(A)
(C)
(D)
=
~
0
No fan defective / lacking power supply
1
BR
2
BL
3
BR and BL
4
FR
5
FR and BR
6
FR and BL
7
FR, BL and BR
8
FL
9
FL, BR
10
FL, BL
11
FL, BL and BR
12
FL, FR
13
FL, FR and BR
14
FL, FR and BL
15
All roof fans defective / lacking power supply
FL
FR
BL
BR
Fig. 4 - Code for roof fan