Troubleshooting – Formax FD 8904B User Manual
Page 22

Malfunction codes
Code Description
Action
1000
Phase is missing / mains input
Electrician! Check onsite fuses.
1010
Incorrect connection of phases / Wrong direct.
of rotation
Electrician! Check rotatory field
1100
Oil temperature too high
Let oil cool down
1110
Sensing device for oil temperature defective
Change sensing device - Contact Service
1200
Motor protective switch has swapped.
Let motor cool down.
1211
Emergency-off is actuated
Reset emergency-off pushbutton
1221
Hopper is open
Close inspection flap
1231
Switch for Counter plate closed” defective “
Switch / Switching mechanism -> Contact service
1232
Counter plate not closed
Close counter plate
1241
Limit switch Counter plate 90° open” defective “
Switch / Switching mechanism -> Contact service
1271
Supervising time Extend press ram” “
Contact service
1272
Supervising time Retract press ram” “
Contact service
1280
Counter plate not locked (induct. switch 0
signal)
Electrician! -> Contact Service
1281
Inductive switch counter plate (no signal change
while opening)
Switch / Switching mechanism -> Contact service
1300
Hardware defective
Electrician! Contact service
1310
Short circuit output Master
Electrician! Contact service
1320
Short circuit output Slave
Electrician! Contact service
TrOuBLEShOOTiNG
If an error/ malfunction occurs in the bailer, the red light fault symbol is displayed. The baler switches off and
a corresponding error message is displayed, see list. The malfunction numbers appear in the error memory.
18