Malfunction codes

Code Description

Action

1000

Phase is missing / mains input

Electrician! Check onsite fuses.

1010

Incorrect connection of phases / Wrong direct.

of rotation

Electrician! Check rotatory field

1100

Oil temperature too high

Let oil cool down

1110

Sensing device for oil temperature defective

Change sensing device - Contact Service

1200

Motor protective switch has swapped.

Let motor cool down.

1211

Emergency-off is actuated

Reset emergency-off pushbutton

1221

Hopper is open

Close inspection flap

1231

Switch for Counter plate closed” defective “

Switch / Switching mechanism -> Contact service

1232

Counter plate not closed

Close counter plate

1241

Limit switch Counter plate 90° open” defective “

Switch / Switching mechanism -> Contact service

1271

Supervising time Extend press ram” “

Contact service

1272

Supervising time Retract press ram” “

Contact service

1280

Counter plate not locked (induct. switch 0

signal)

Electrician! -> Contact Service

1281

Inductive switch counter plate (no signal change

while opening)

Switch / Switching mechanism -> Contact service

1300

Hardware defective

Electrician! Contact service

1310

Short circuit output Master

Electrician! Contact service

1320

Short circuit output Slave

Electrician! Contact service

TrOuBLEShOOTiNG

If an error/ malfunction occurs in the bailer, the red light fault symbol is displayed. The baler switches off and

a corresponding error message is displayed, see list. The malfunction numbers appear in the error memory.

18