Retrofitting – Flowserve UNA 38 User Manual
Page 17
7
Retrofitting
GESTRA steam traps can be retrofitted with different control units.
WINIX
®
50 is a registered trademark of WINIX GmbH, Norderstedt
Cleaning /exchanging the control unit
. Take heed of the “Danger” note on page 4.
. Undo the hexagon nuts
A, remove the sleeves B from the expansion bolts P, and take off
the cover
M.
3. Undo the union nut
X and take it out of the body together with the control unit E, r or ; (UNA 38);
alternatively, undo and remove the hexagon socket-head screws
T, and take out the control unit
r or ; (UNA 39).
4. Replace the control unit in case of visible signs of wear or damage.
5. Clean the body, internals and all gasket surfaces.
6. Apply heat-resistant lubricant to all threads and the seating surfaces of the control unit and cover
(use e.g. WINIX
®
50).
7. Attach the control unit
E, r or ; (UNA 38) with the union nut and align it within the body so that the
float ball can move vertically. Tighten the union nut. Insert a new gasket
U for control unit r or ;
(UNA 39), put on the control unit and tighten the hexagon socket-head screws
T evenly crosswise.
For the torques, see the table “Torques” on page 6.
8. Insert a new body gasket
Q.
9. Put the cover onto the body and push the sleeves
B onto the expansion bolts P. Tighten the
hexagon nuts
A evenly crosswise in several stages to the values specified in the “Torques” table.
2
2
2
2
Tools
n
Combination spanner A.F. 7, 9, , 4, 30, 46 mm to DIN 33, form B
n
Allen key A.F. 5, 8 mm to ISO 936
n
Torque spanner 0–60 Nm, 60–0 Nm, 0–300 Nm to DIN ISO 6789
Torques
Item
Designation
Torque [Nm]
UNA 38
UNA 39
A
Hexagon nut
70
340
T
Hexagon-socket screw
(UNA 39)
40
X
Union nut
(UNA 38)
0
P
Expansion bolts
0
0
C
Bimetallic air vent
90
I
Hand vent valve
70
70
K
Float lifting lever
0
O
Plug
70
70
F
Plug
0