Maintenance – Flowserve UNA 38 User Manual
Page 15
5
WINIX
®
50 is a registered trademark of WINIX GmbH, Norderstedt
Maintenance
GESTRA steam traps of the type UNA do not require any special maintenance.
However, if the steam trap is to be used in a new installation which has not been flushed yet,
it is advisable to check and – if required – clean the trap.
The UNA steam traps can be checked for steam loss during operation by using the GESTRA ultrasonic
measuring unit VAPOPHONE
®
or TRAPtest
®
.
In case of steam loss, clean the valve and/or replace the control unit or orifice.
Checking the steam trap
Cleaning/exchanging the control unit
. Take heed of the “Danger” note on page 4.
. Undo the hexagon nuts
k, remove the sleeves l from the expansion bolts z, and take off
the cover
w.
3. Unscrew and remove the bimetallic air vent
C; take out the gasket D.
4. Install a new bimetallic air vent
C together with a new gasket. For the torque, see the table “Torques”
on page 6.
5. Insert a new body gasket
:.
6. Put the cover onto the body and push the sleeves
l onto the expansion bolts z. Tighten the hexagon
nuts
k evenly crosswise in several stages to the values specified in the “Torques” table.
Changing the bimetallic air vent (UNA 38)
. Take heed of the “Danger” note on page 4.
. Undo the hexagon nuts
A, remove the sleeves B from the expansion bolts P, and take off
the cover
M.
3. Undo the union nut
X and take it out of the body together with the control unit E, r or ; (UNA 38);
alternatively, undo and remove the hexagon socket-head screws
T, and take out the control unit
r or ; (UNA 39).
4. Replace the control unit in case of visible signs of wear or damage.
5. Clean the body, internals and all gasket surfaces.
6. Apply heat-resistant lubricant to all threads and the seating surfaces of the control unit and cover
(use e.g. WINIX
®
50).
7. Attach the control unit
E, r or ; (UNA 38) with the union nut and align it within the body so that the
float ball can move vertically. Tighten the union nut. Insert a new gasket
U for control unit r or ;
(UNA 39), put on the control unit and tighten the hexagon socket-head screws
T evenly crosswise.
For the torques, see the table “Torques” on page 6.
8. Insert a new body gasket
Q.
9. Put the cover onto the body and push the sleeves
B onto the expansion bolts P. Tighten the
hexagon nuts
A evenly crosswise in several stages to the values specified in the “Torques” table.
2
2
2
2