beautypg.com

9 mechanical stops – Flowserve LY Series Limitorque User Manual

Page 22

background image

Limitorque LY Series: LY 1001, LY 2001 and LY 3001 FCD LMENIM1501-00 – 11/11

22

5.9 Mechanical Stops

5.9.1 Setting the CLOSED Mechanical Stop on the LY 1001

Table 5.5 – Mechanical Stop Set Screws

Unit Type

Mechanical Stop Set Screw Size

Set Screw Size

LY 1001

3/8-16 x 1.25"

3/8-16 x 0.375"

Piece numbers refer to Figure 5.10.

1. Set CLOSE Mechanical Stop Set Screw (piece #58) by removing the Set Screw (piece #59).

2. Using the Handwheel, turn the valve to the CLOSE position. Make sure the valve is fully seated

before setting the mechanical stop.

3. Rotate Mechanical Stop Set Screw (piece #58) in the CW direction until contact with the Torque Nut

(piece #32) occurs. (See Figure 5.9.)

4. Back-off Mechanical Stop Set Screw (CCW direction) approximately 11/2 turns.

5. Reinstall Set Screw (piece #59).

6. Manually operate the actuator through the close limit to assure setting is correct.

NOTE:

The Mechanical Stops are intended to protect the equipment from overtravel if a Limit Switch

fails. The valve should not torque-out against the Mechanical Stop Set Screw during normal OPEN/
CLOSE cycles.

Figure 5.10 – Mechanical Stop Set Screw Adjusted to Torque Nut Contact Point on LY 1001

#59 Set Screw

#58 Mechanical

Stop Set Screw

#32 Torque Nut

Torque Nut &

Mechanical Stop Screw

positioned at contact point

CCW to Open

Mechanical Stop

Set Screws

OPEN CLOSED

LY 1001 Bottom View