3
Torques
All torques indicated in the table are based at a room temperature of 0 °C.
Maintenance
continued
Tools
■
Spanner A. F. 3 mm, DIN 33, Form B
■
Spanner A. F. 7 mm, DIN 33, Form B
■
Spanner A. F. 8 mm, DIN 33, Form B
■
Spanner A. F. 3 mm, DIN 33, Form B
■
Spanner A. F. 36 mm, DIN 33, Form B
■
Spanner A. F. 4 mm, DIN 33, Form B
■
Torque spanner Nm, ISO 6789
■
Torque spanner 0 0 Nm, ISO 6789
■
Torque spanner 80 400 Nm, ISO 6789
■
Socket spanner 3 x 50, DIN 3
■
Punch 0 x 00, made of steel
■
Punch 0 x 00, made of CuZn (brass)
■
Pin punch 8 x 50, DIN 6450 C
■
Grease gun (for valve plug)
Item
Intermittent valves for removing boiler sludge
Torques [Nm]
G
PA 46, PA 47, MPA 46, MPA 47
350
O
PA 46, PA 47, MPA 46, MPA 47
55
W
PA 46, PA 47, MPA 46, MPA 47
0
U
PA 46, PA 47
60
Y
MPA 46, MPA 47
0
5
MPA 46, MPA 47
5